HOME PRODUCTS SERVICES COMPANY
INFO
SPECIALS CONTACT
US

Topcon TRC-NW6S Non-Mydriatic Retinal Camera
An advanced solution to Non-Mydriatic Retinal Imaging In this age of rapid advances in digital and electronic technology, Topcon leads the field with the versatile non-mydriatic retinal camera, the TRC-NW6S. When combined with the latest CCD camera technology and IMAGEnet Lite imaging software, the fully integrated imaging system produces sharp - color accurate images that make diagnosis faster and more accurate.

The total imaging solution includes the TRC-NW6S and AutoMosaic software, which create panoramic images of the retina using the built-in peripheral fixation points of the TRC-NW6S.

The TRC-NW6S is the core component of this imaging solution and provides a state of the art electronic imaging interface that will stay current with future technological changes.


Features
Innovative Peripheral Internal Fixation Points
The TRC-NW6S incorporates one central and eight peripheral fixation points that cover 85 degrees of the retina. There are several fixation patterns provided, which can be chosen and set as defaults. An alignment scale will appear on the monitor for each fixation point to give precise image positioning.

IMAGEnet Lite and AutoMosaic Software (optional)
When connected with the IMAGEnet,"Lite System, the TRC-NW6S provides a total imaging solution for advanced retinal imaging. All information from the TRC-NW6S, including - right eye or left eye and fixation positions, is automatically transferred to IMAGEnet Lite, along with the images. IMAGEnet Lite's AutoMosaic software is especially designed for the TRC-NW6S to create a mosaic image from tip to 9 different fields of the retina. The complete system provides image capture, viewing, editing, networking and storage capability.

Easy Alignment
Alignment is easily accomplished by overlapping the two bright spots on the monitor, assuring fast and precise operation. Because the alignment spot is always in the monitor view, the operation is easy and reliable.

Easy Focusing
Focusing is easily accomplished by aligning the split lines within the focusing bar. For better monitor viewing, the focusing bar may be turned on or off.

New Ergonomic Design
A totally new design makes the TRC-NW6S compact and ergonomic. The instrument controls, viewing monitor and patient are all in direct alignment for easy access, making it easy to obtain excellent retinal images.

Auto Flash Intensity
When the angle of coverage is changed by the user, the existing flash setting will be automatically Corrected. If required, a manual setting of up to 9 steps is also possible.

Illuminated Operation Panel
An illuminated operational panel makes operation easy in dim light settings.

Electric Chinrest Movement for Operational Ease
The control buttons for the electrical elevation of the chinrest are conveniently located next to the joystick for quick operation during photography.

Small Pupil Capability
It is possible to photograph through a pupil as small as 3.7mm by using the 30 degree angle of coverage.

Ready for Tele-Ophthalmology
The TRC-NW6S and IMAGEnet Lite software package is ideal for, sharing images with trained practitioners when screening patients from a remote location.

AutoMosaic Imaging
The AutoMosaic software module for IMAGEnet Lite easily creates a single image panoramic view of the retina. The software includes image contrast and edge adjustments to create a realistic panoramic view.

Anterior Photography
In addition to retinal images, the TRC-NW6S can easily capture images of the anterior portion of the eye.

Full Screen Image with 30° Angle of Coverage
In addition to the 45° angle, it is possible to use the 30° angle coverage to capture an enlarged image of the retinal surface. This magnified image contains more detailed information and is especially helpful when evaluating the optic disc.

Required Additional Equipment
The TRC-NW6S requires a digital imaging system to capture and store the images. Topcon has developed the IMAGEnet- Lite software package as an advanced imaging solution for the TRC-NW6S. Various versions and configurations of the IMAGEnet-Lite System are available.

Optional Accessory
Adjustable Instrument Table: AIT-15

Specifications

Angle of coverage 45°, 30°

Pupil diameter for photography 45°: 4.0mm ø or more, 30°: 3.7mm ø or more

Patient diopter correction range Without correction lens :-13D to +12D (where split lines are used)
With minus correction lens : -12D to -33D
With plus correction lens : +9D to +40D

Peripheral fixation Internal 8 points

Flash Intensity Automatically changed corresponding to the angle of 45° and 30°
Manual setting in 9 steps is also available

Data picturing Simultaneously name plate imaging

Data filing system Data (R/L, angle and 8 fixed position) output to IMAGEnet Lite is available

Power source Frequency: 50/60 Hz Voltage: AC110, 120, 230, 240V selectable

Weight Body: 24.5kg, TV relay lens: 1.0kg

Dimensions 272(W)x 505(D)x 530(H)mm with TV relay lens

Power consumption 400VA(Maximum), 100VA(Normal)

Toll Free 1-800-755-5919
©2008 Latham & Phillips Ophthalmic Products Inc. All rights reserved.