• 100% eye fixation control – if fixation is lost, no stimulus is presented.
• Diagnostic programs with test stages prioritising the most crucial field areas.
• Automated pupil measurement allowing accurate assessment and comparison of data.
• Optional fast software for significantly shorter examinations avoid errors caused by patient and retinal fatigue.
|
| |
| Speed and Ease of Use |
| |
• Separate examination- and PC control unit allows the technician to work comfortably in ambient light conditions.
• Offers the most complete library of standard diagnostic programs and test strategies.
• With the Tendency Oriented Perimetry (TOP) test strategy, a full threshold examination takes less than 2:30 min.
• The clear Seven-in-One print-out presents the most complete information needed for the assessment of the results.
• During the examination, a real time display of statistical data provides on-line information about the status of the patient’s visual field.
• The test procedure can be interrupted at any time and continued later without losing data.
• Flexible and user defined test parameter settings for additional custom test programs serving scientific studies.
• Network compatible – allowing examination results to be viewed on more than one monitor.
• Software is easily upgradeable to the latest version by downloading the software from Internet.
|
| |
| Patient Comfort |
| |
The instrument table offers ample legroom and access for any type of wheel chair.
• The spherical Goldmann bowl ensures accurate static and kinetic perimetry to 90° periphery.
• Faster testing results in better patient cooperation.
• Patients are encouraged to blink regularly without the risk of introducing erroneous results.
• Seated separately from the control unit allows the patient to work in a more quiet environment.
• Goldmann Kinetic Perimetry*
|
| |
| Fixation control |
| Real time infrared eye control automatically repeating stimuli that interfere with blinking and delaying stimuli presentation during non fixation
|
| |
| Pupil measure |
| Automatic averaging pupil size measurement
|
| |
| Easy follow up |
| Follow up button ensuring identical test parameters**
|
| |
| Flexible test procedures |
Screening programs can be used for threshold testing
Central programs can be extended to the periphery
|
| |
| Procedure codes |
| Standard operating procedures with all parameters and printout definitions can be automated
|
| |
| Reaction time |
| Adaptive interstimulus time for static perimetry,
patented correction for reaction time in kinetic perimetry*
|
| |
| Specifications |
|
| Optical specifications |
| |
| Optical System |
Spherical Goldmann Cupola |
| |
|
| Usable temporal range |
Horizontal +89°/-89°, Vertical +60°/-67° |
| |
|
| Stimulus generation |
Mirror projection systemL_atham_and_P_hillips |
| |
|
| Resolution |
0,1° |
| |
|
| Stimulus duration |
100, 200, 500, 1000, infinite |
| |
|
| Dynamic range |
47dB (max. 1910cd/m²) |
| |
|
| Stimulus colors |
White, Blue* (440nm), Red* (610nm) |
| |
|
| Stimulus size |
Goldmann I, II, III, IV, V |
| |
|
| Background |
1,27cd/m² / 10cd/m² (white), 100cd/m² (yellow )* |
|
| Reliability measures |
| |
| Fixation |
Realtime blink and fixation control (60 frames/second) |
| |
|
| Eye position |
Automated Eye Tracking*,** |
| |
|
| Lensholder |
Automated positioning and distance adjustment** |
| |
|
| Head position |
Non contact head sensor |
| |
|
| Test speed |
Adaptive test speed based on patient's reaction time |
|
| Test methods |
| |
| White/White |
Standard automated perimetry |
| |
|
| Blue/Yellow |
Short wavelength automated perimetry* |
| |
|
| Red/White |
Color perimetry*,** |
| |
|
| Kinetic |
Manual and Automated Goldmann Kinetic perimetry* |
| |
|
| Flicker |
CFF Critical Flicker Fusion Frequency perimetry*,** |
|
| Threshold & Screening test strategies |
| |
| Normal strategy |
8-12 min (4-2-1 bracketing strategy) |
| |
|
| Dynamic strategy |
5-8 min (adaptive step size) |
| |
|
| TOP* |
2-3 min (Tendency Oriented Perimetry)*L_atham_and_P_hillips |
| |
|
| LVS |
Low vision (Bottom up) Goldmann V strategy |
| |
|
| 2-LT |
3 zone (normal, relative, absolute defect) |
| |
|
| 1-LT |
2 level (seen, non seen) |
| |
|
| Multi-phase strategy |
Consecutive threshold testing of relative defects and normal areas |
|
| Program library |
| |
| M |
Physiological macular test 5°/ 12°/ 30° |
| |
|
| G |
Physiological general test 30°/ 60° |
| |
|
| 32 |
Equidistant 30° testL_atham_and_P_hillips |
| |
|
| 07 |
Cortically based overview test to 75° |
| |
|
| LVC, LVP |
Low vision programs for end stage follow up |
| |
|
| D1, N1 |
Programs for Diabetes, Neuro-ophthalmology |
| |
|
| BT, BG, FG, Esterman |
General legal tests** |
| |
|
| Country dependent |
Country dependent static and kinetic expert opinion tests**
|
| |
|
| Custom Test* |
Individual test programming with a graphical user interface*,**
|
|
| Electrical and mechanical specifications |
| |
| Power requirements |
100 – 120VAC / 220 - 240 VAC 50/60Hz |
| |
|
| Power consumption |
145VA / 165 VA |
| |
|
| Measures (W x L x H) |
648mm x 519mm x 796 mmL_atham_and_P_hillips |
| |
|
| Weight |
25 kg |
| |
|
| Temperature (operating) |
+15°C to +40°C |
| |
|
| Light source lifespan |
> 20,000 hours for stimulus, background and fixation |
| |
|
| Interface |
Ethernet T-100 |
| |
|
| Classification |
Class I, Type B |
| |
|
| Conformity |
CE: 93/42/EEC, 89/336/EEC, and conformity module A CSA C & US |
| |
|
| Compliance |
IEC / EN60601-1:2005, EN 60601-1-2: 2001 + prA1, IEC 60601-1-2: 2001 + A1: 2004, EN ISO 15004-1: 2006, EN ISO 12866: 1999 + AC:2000, IEC 60825-1: 2001-08 Ed. 1.2, CIE S 009/E: 2002 |
|
| |
| * Pro version (available as options for the Octopus 900 Basic) |
| ** Under development and may not be available at the time of publication (July 07) |
| |