Patented Soft-Touch probe assures low pressure hand-held contact reducing the need for chin rest and reclined immersion measurements.
|
| |
| Probes |
| 10MHz, focused, internal fixation; solidtip, Soft-Touch, or immersion |
| |
| Formulas |
| Choice of 3 from Holladay, Regression II, Theoretic / T, Binkhorst and Hoffer-Q |
| |
| Modes |
| Automatic, Manual and Diagnostic; Cataract, Dense Cataract, Aphakic, Pseudophakic |
| |
| Measure |
| ACD, Lens, Vitreous and Axial Length |
| |
| Review |
| Stored A-scan patterns, A-scan measurements and statistics |
| |
| Statistics |
| Average, Standard Deviation, Range, and Maximum Difference from average |
| |
| Calculations |
2 tables of 9 operator selected IOL powers vs. refraction. Personalized A-constants and Surgeon Factors |
| |
| Displays |
| Multiple screens available for tabled, summarized and compared calculations |
| |
| Memory |
| Stores 5 scans and measurements, selected formula, IOL constants and users name |
| |
| Accuracy |
Electronic ±0.0375mm Clinical ±0.1mm |
| |
| Range |
Automatic Mode 18 to 33mm Manual Mode 0.5 to 35mm |
| |
| Calibration |
| Automatic with built-in calibration cylinder |
| |
| Report data |
| Patients Name, ID, Eye examined, K-readings, Users Name, Date and Time |
| |
| A-Scan options |
• Immersion capability
• Alphanumeric keyboard controller
• Soft-Touch A-scan probe
• Adjustable tilt handle
|
|
| B-Scan Features |
| Probe |
| 10MHz. focused, 30 frames per sec., 128 lines, (256 interpolated) |
| |
| Measurements |
| Distance: Axial 0.12mm., Lateral 0.24mm |
| |
| Area |
| 0.12mm² |
| |
| Amplifiers |
| Logarithmic, Linear, and S-CurveL_atham_and_P_hillips |
| |
| Magnification |
| Continuous Zoom, and Pan, joy stick controlled from 0.5X to 2.0X |
| |
| Resolution |
| 1024 x 480 pixels, with optimal tissue resolution of 0.15mm axial and 0.3mm lateral |
| |
| Processing |
| Reject below level, saturate above or selected level, enhance contour and texture, and smooth image |
| |
| Memory |
| Dual for real-time and processed image |
| |
| Freeze |
| Foot pedal or control panel activated |
| |
| Image |
| B-scan with simultaneous selectable vector A-scan |
| |
| Gray scale |
| 128 levels |
| |
| Display |
60° sector fan, Gray Scale, B/a presentation (B emphasized) or A/b (A emphasized), Gain, Electronic Scale, TVG, Amplifier, OD/OS, Velocity, Probe Orientation, Patient Name, Date |
| |
| B-Scan options |
• Color coded image generation (RGB)
• Mobile instrument cart w/ keyboard shelf
• Adjustable tilt handle
• Alphanumeric keyboard controller |